基本的SNMP V3 配置,为了能用DM连上北电交换机
#
# SNMP V3 GROUP MEMBERSHIP CONFIGURATION
#
snmp-v3 group-member create test usm test
#
# SNMP V3 GROUP ACCESS CONFIGURATION
#
snmp-v3 group-access create test "" usm noAuthNoPriv
snmp-v3 group-access view test "" usm noAuthNoPriv read "root" write "root" notify "root"
snmp-v3 usm create test
----- 新增加一个 hello
#
# SNMP V3 GROUP MEMBERSHIP CONFIGURATION
#
snmp-v3 group-member create hello usm hello
#
# SNMP V3 GROUP ACCESS CONFIGURATION
#
snmp-v3 group-access create hello "" usm noAuthNoPriv
snmp-v3 group-access view hello "" usm noAuthNoPriv read "root" write "root" notify "root"
# 增加的usm用户
snmp-v3 usm create test